JOURNAL OF THE CZECH PHARMACEUTICAL SOCIETY AND THE SLOVAK PHARMACEUTICAL SOCIETY

Čes. slov. farm. 2005, 54(4):173-177

HPLC Separation of Racemic Basic Esters of Alkoxyphenylcarbamic Acid Using Two Teicoplanin Chiral Stationary Phases

T. Rojkovičová1, J. Lehotay1, J. Čižmárik2
1 Slovenská technická univerzita v Bratislave, Fakulta chemickej a potravinárskej technológie, Katedra analytickej chémie
2 Farmaceutická fakulta Univerzity Komenského v Bratislave, Katedra farmaceutickej chémie

This paper presents the results obtained with the use of two chiral stationary phases (CSP), based on a glycopeptide antibiotic agent - teicoplanin aglycone (CHIROBIOTIC TAG) and methylated teicoplanin aglycon m-TAG. Twenty-one racemic mixtures of 1-methyl-2-piperidinoethylesters of 2-, 3- a 4-alkoxyphenylcarbamic acid were examined. The investigation included interaction between separated substances and CSP, and the effect of separation of the enantiomers under study on the value of the resolution factor (Rij) under identical chromatographic conditions with the use of the method of high-performance liquid chromatography (HPLC). On the basis of obtained results, it is possible to report that CSP-CHIROBIOTIC TAG is more advantageous for these racemates, because it does not contain a saccharide part, with decrease the possibility of non-polar interactions which exert a negative effect on the Rij value.

Keywords: teicoplanin aglycone; m-TAG; basic derivates of phenylcarbamic acid; HPLC; separation of enantiomers; local anaesthetics

Received: April 26, 2004; Accepted: August 15, 2004; Published: April 1, 2005  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Rojkovičová T, Lehotay J, Čižmárik J. HPLC Separation of Racemic Basic Esters of Alkoxyphenylcarbamic Acid Using Two Teicoplanin Chiral Stationary Phases. Čes. slov. farm. 2005;54(4):173-177.
Download citation

References

  1. kyseliny majú predovšetkým polárne interakcie, nepolárne interakcie majú negatívny účinok. V prípade použitia m-TAG CSF pre všetky študované enantioméry pri nulovom prídavku dietylamínu k enantioseparácii nedochádzalo (Rij=0). Pri použití optimálnej mobilnej fázy sa hodnoty Rij pohybovali v rozpätí 1,7~3,0 na kolóne CHIROBIOTIK TAG 24), v prípade m-TAG Rij boli 1,2~1,8. Separácie racemátov sa uskutočnili na oboch chirálnych kolónach za rovnakých chroma
  2. Armstrong, D. W., Tang, Y., Chen, S. et al.: Anal. Chem., 1994; 66, 1473-1484. Go to original source...
  3. Armstrong, D. W.; Lie, Y. B.; Ekborg-Ott, K. H.: Chirality 1995; 7, 474-497. Go to original source...
  4. Aboul-Enein, H., Serignese, V.: Chirality, 1998; 10, 358-361. Go to original source...
  5. Scott, R. P. W., Beesley, T. E.: Analyst, 1999; 124, 713-719. Go to original source...
  6. Wang, A. X., Lee, J. T., Beesley, T. E.: LC GC, 2000; 18(6), 626-639.
  7. Aboul-Enein, H. Y., Ali, I.: Il Farmaco 2002, 57, 513-529. Go to original source... Go to PubMed...
  8. Armstrong, D. W., Rundlett, K., Reid, G. L.: Anal. Chem., 1994; 66, 1690-1695. Go to original source... Go to PubMed...
  9. Doležalová, M., Tkaczyková, M.: Chirality, 1999; 11, 394-403. Go to original source...
  10. Doležalová, M., Tkaczyková, M.: J. Pharm. and Biomed. Analysis, 1999; 19, 555-567. Go to original source... Go to PubMed...
  11. Péter, A., Torok, G., Armstrong, D. W.: J. Chromatogr. A, 1998; 793, 283-296. Go to original source... Go to PubMed...
  12. Petritis, K., Valleix, A., Elfakir, C., Dreux, M.: J. Chromatogr. A, 2001; 913, 331-340. Go to original source... Go to PubMed...
  13. Schlauch, M., Frahm, A. W.: J. Chromatogr. A, 2000; 868, 197-207. Go to original source... Go to PubMed...
  14. Péter, A., Török, G., Armstrong, D. W. et al.: J. Chromatogr. A, 2000; 904, 1-15. Go to original source... Go to PubMed...
  15. Péter, A., Lázár, L., Filop, F., Armstrong, D. W.: J. Chromatogr. A, 2001; 926, 229-238. Go to original source... Go to PubMed...
  16. Hui, F., Ekborg-Ott, K. H., Armstrong, D. W.: J. Chromatogr. A, 2001; 906, 91-103. Go to original source... Go to PubMed...
  17. Berthod, A., Chen, X., Kullman, J. P., Armstrong, D. W.: Anal. Chem. 2000; 72, 1767. Go to original source... Go to PubMed...
  18. Fried, K. M., Koch, P., Wainer, I. W.: Chirality, 1998; 10, 484-491. Go to original source...
  19. Lehotay, J., Hroboňová, K., Čižmárik, J. et al.: J. Liq. Chrom. & Rel. Technol., 2001; 24 (5), 609-624.
  20. Mistry, B., Leslie, J. L., Eddington, N. D.: J. Chromatogr. B, 2001; 758, 153-161. Go to original source... Go to PubMed...
  21. Svensson, L. A., Donnecke, J., Karlsson, K. et al.: Chirality, 2000; 12, 606-613. Go to original source...
  22. Hroboňová, K., Lehotay, J., Čižmáriková, R., Armstrong, D. W.: J. Liq. Chrom. & Rel. Technol., 2001; 24 (15), 2225-2237 Go to original source...
  23. Ďungelová, J., Lehotay, J., Hroboňová, K. et al.: J. Liq. Chrom. & Rel. Technol., 2002; 25(2), 299-312.
  24. Aboul-Enein, H. Y., Ali, I.: Chromatogr., 2000; 52, 679691.
  25. Rojkovičová, T., Lehotay, J., Ďungelová, J. et al.: J. Liq. Chrom. & Rel. Technol., 2002; 25, 2723.




Czech and Slovak Pharmacy

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.