Čes. slov. farm. 2006, 55(3):124-130
Interconversion of Stereochemically Unstable Chiral Drugs Part III: Using ß-Cyclodextrin as a Chiral Stationary Phase for HPLC Separation of Diazepam Conformers Coupled with an Off-line NMR Experiment
- 1 Slovenská technická univerzita v Bratislave, Fakulta chemickej a potravinárskej technológie, Ústav analytickej chémie, SR
- 2 Farmaceutická fakulta Univerzity Komenského v Bratislave, Katedra farmaceutickej chémie, SR
Chiral ß-cyclodextrin was used to separate diazepam conformers. Several mobile phases of the composition acetonitrile/acetate buffer 200 mmol/l (pH=3.3, 5.5, 6.5) were employed for this purpose. As follows, the influence of addition of chiral ß-cyclodextrin to the mobile phase on diazepam separation was studied. The interconversion was a concurrence process of separation, resulting from stereolability of the diazepam molecule. The influences of temperature, flow rate, pH, and ionic strength of the mobile phase on interconversion and chromatographic parameters (retention factor and selectivity coefficient) were studied. Complementary off-line NMR measurements were carried out with the goal to confirm the structure of diazepam in the presence of an acid mobile phase.
Keywords: interconversion and separation; diazepam; HPLC; NMR
Received: January 16, 2006; Accepted: March 13, 2006; Published: March 1, 2006 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Fedurcová, A., Lehotay J., Čižmárik J.: Interkonverzia stereochemicky nestálych chirálnych liečiv - využitie chromatografických techník na štúdium enantiomerizácie, výpočet termodynamických parametrov. Časť I: Teoretické aspekty. Čes. slov. Farm., 2005; 54, 256-261.
- Trapp, O., Trapp, G., Schurig, V.: Direct Calculation and Computer simulation of the enantiomerization barrier of oxazepam in dynamic HPLC experiments - a comparative study. J. Biochem. Biophys. Meth., 2002; 54, 301-313.
Go to original source...
Go to PubMed...
- Nishikawa, T., Hayashi, Y., Suzuki, S. et al.: On column enantiomerization of 3-hydroxybenzodiazepines during liquid chromatoraphy with optical rotation detection. J. Chromatogr. A, 1997; 767, 93-100.
Go to original source...
- Wang, S., Porter, M. D.: Enantiomers Separation of benzodiazepines by electrochemically modulated liquid chromatography. J. Chromatogr. A, 1998; 828, 157-166.
Go to original source...
- Stalcup, A. M., Wu, W., Williams, K. L.: Separation of benzodiazepines on a new carbohydrate-based chiral stationary phase for HPLC. Biomed. Chromatogr., 1997; 11, 325-330.
Go to original source...
- Paizs, B., Simonyi, M.: Ring inversion barrier of diazepam and derivates: Ab initio study., Chirality, 1999; 11, 651-658.
Go to original source...
- Sjödin, T., Roosdorp, N., Sjöholm, I.: Biochem. Pharmacol., 1986; 25, 2131.
Go to original source...
Go to PubMed...
- Loftsson, T., Gudmundsdóttir, H., Sigurjónsdóttir, J. F. et al.: Cyclodextrin Solubilization of benzodiazepines: formulation of midazolam nasal spray. Inter. J. Pharmac., 2001; 212, 29-40.
Go to original source...
Go to PubMed...