JOURNAL OF THE CZECH PHARMACEUTICAL SOCIETY AND THE SLOVAK PHARMACEUTICAL SOCIETY

Čes. slov. farm. 2002, 51(3):112-120

Immunoanalytical Methods of Analysis of Cyclosporine A

K. Šafarčík, I. Komzáková, V. Bartoš, M. Grundmann
Ústav klinické farmakologie FNsP a Zdravotně sociální fakulta Ostravské Univerzity, Ostrava
KIinika nukleární medicíny FNsP, Ostrava-Poroba
KIinika farmakologie lékařské fakulty Univerzity Palackého, Olomouc

The standard method for determination of CyA in blond is a good validated HPLC method. HPLC methods esere developed which make it possible to determine not only the parem drog, bot also the main metabolites of CyA: AMI (M17), AM9 (Ml), and AM4N (M21). HPLC methods for determination of CyA are very laborious and expensive. Most transplantation centres in the world ose immunoanalytical methods for TDM of CyA. In retem years there has been an increase in the number of users of nonisotopic automated methods (Abbott TDx mono, AxSYM, Dade-Behring EMIT® or Microgenic Cedia), which render instantaneous analysis possible. The analysis of the results of CyA in the blond in patients after transplantation shows tkat all immunoanalytical methods overestimate the concentration of CyA against HPLC results. The usually presented series of results is as follows: HPLC

Keywords: cyclosporine A; CyA metabolites; HPLC; RIA; nonisotopic immunoassays

Published: March 1, 2002  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Šafarčík K, Komzáková I, Bartoš V, Grundmann M. Immunoanalytical Methods of Analysis of Cyclosporine A. Čes. slov. farm. 2002;51(3):112-120.
Download citation




Czech and Slovak Pharmacy

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.