Čes. slov. farm. 2020, 69(5):218-221 | DOI: 10.36290/csf.2020.030
Automated preparation of radiopharmaceuticals as a tool of radiation protection optimisation of staff
- 1 Masarykův onkologický ústav, Ústavní lékárna, Brno
- 2 Oddělení nukleární medicíny, Fakultní nemocnice Hradec Králové
Preparation of radiopharmaceuticals means everyday exposure to ionizing radiation for pharmaceutical workers. Manual preparation of positron radio-pharmaceuticals may be a risk in exceeding the legisla-tive limits for radiation workers, in particular in finger dosimetry. Instrumental methods of preparation of radiopharmaceuticals can serve as an effective tool of radiation protection. The present study deals with the evaluation of the results of personal dosimetry in workers preparing the radiopharmaceutical 18F-FDG with the use of instrumental methods of preparation of this radiopharmaceutical. The results of the paper show a clear decrease in the values of finger dosimetry and a minute increase in the values of whole-body dosimetry in the cohort of pharmaceutical personnel. The evaluation thus shows a clear contribution of instrumental methods of preparation of the radiopharmaceutical 18F-FDG to the results of finger dosimetry of pharmaceutical personnel.
Keywords: automated preparation of radiopharma-ceuticals; radiation protection of staff; radiopharmacy
Received: November 3, 2020; Accepted: November 6, 2020; Published: May 1, 2020 Show citation
References
- Demir M., Demir B., Yasar D., Sayman H. B., Halac M., Ahmed A. S., Ozcan K., Uslu I. Radiation doses to technologists working with 18F-FDG in PET center with high patient capacity. Nukleonika 2010; 55(1), 107-112.
- Roberts F. O., Gunawardana D. H., Pathmaraj K., Wallance A., U P. L., Berlangieri S. U., Graeme J. O'Keefe, Rowe C. C., Scott A. M. J. Radiation dose to PET technologists and strategies to lower occupational exposure. J. Nucl. Med. Technol. 2005; 33, 44-47.
- Guillet B., Quentin P., Waultier S., Bourrelly M., Pisano P., Mundler O. Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET. J. Nucl. Med. Technol. 2005; 33(3), 175-179.
- Rohren E. M., Turkington T. G., Coleman E. Clinical applications of PET in oncology. Radiology 2004; 231, 305-332.
Go to original source...
Go to PubMed...
- Bixler A., Springer G., Lovas R. Practical aspects of radiation safety for using fluorine-18. J. Nucl. Med. Technol. 1999; 27(1), 14-16.
- Antic V., Ciraj-Bjelac O., Stankovic J., Arandjic D., Todorovic N., Lucic S. Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia. Radiat. Prot. Dosim. 2014; 162(4), 577-585.
Go to original source...
Go to PubMed...
- Schleipman A. R., Gerbaudo V. H. Occupational Radiation Dosimetry Assessment Using an Automated Infusion Device for Positron-Emitting Radiotracers. J. Nucl. Med. Technol. 2012; 40(4), 244-248.
Go to original source...
Go to PubMed...
- Vanhavere F., Carinou E., Donadill L., Ginjaume M., Jankowski J., Rimpler A., Merce M. S. An overview of extremity dosimetry in medical applications. Radiat. Prot. Dosim. 2008; 123(1-3), 350-355.
Go to original source...
Go to PubMed...
- Lecchi M., Lucignani G., Maioli C., Ignelzi G., del Sole A. Validation of a new protocol for 18F-FDG infusion using an automatic combined dispenser and injector system. Eur. J. Nucl. Med. Mol. Imag. 2012; 39, 1720-1729.
Go to original source...
Go to PubMed...
- Budinsky M., Kozakova S. Experience with instrumental methods in radiopharmacy as a tool of radiation protection optimization Eur. J. Oncol. Pharm. 2018; 1, 0002.
Go to original source...
- Covens P., Berus D., Vanhavere F., Caveliers V. The introduction automated dispensing and injection during PET procedures a step in the optimisation of extremity doses and whole body doses of nuclear medicine staff. Radiat. Prot. Dosim. 2010; 140(3), 250-258.
Go to original source...
Go to PubMed...
- Nazififard M., Mahdizadeh S., Meigooni A. S., Alavi M., Suh K. Y. A novel device for automatic withdrawal and accurate calibration of 99mtechnetium radiopharmaceuticals to minimise radiation exposure to nuclear medicine staff and patient. Rad. Prot. Dosim. 2012; 151, 469-477.
Go to original source...
Go to PubMed...
- Lindner O., Busch F., Burchert W. Performance of a device to minimise radiation dose to the hands during radioactive syringe calibration. Eur. J. Nucl. Med. Mol. Imag. 2003; 30, 819-825.
Go to original source...
Go to PubMed...
- Nazififard M., Mahdizadeh S., Suh K. Y. Automated dispensing and calibrating of diagnostic radiopharmaceuticals. Radiat. Prot. Dosim. 2013; 154, 510-516.
Go to original source...
Go to PubMed...