JOURNAL OF THE CZECH PHARMACEUTICAL SOCIETY AND THE SLOVAK PHARMACEUTICAL SOCIETY

Čes. slov. farm. 2020, 69(5):218-221 | DOI: 10.36290/csf.2020.030

Automated preparation of radiopharmaceuticals as a tool of radiation protection optimisation of staff

Michal Budinský1,*, Petr Vyšinský1, Stanislav Synek1, Kateřina Žilková2
1 Masarykův onkologický ústav, Ústavní lékárna, Brno
2 Oddělení nukleární medicíny, Fakultní nemocnice Hradec Králové

Preparation of radiopharmaceuticals means everyday exposure to ionizing radiation for pharmaceutical workers. Manual preparation of positron radio-pharmaceuticals may be a risk in exceeding the legisla-tive limits for radiation workers, in particular in finger dosimetry. Instrumental methods of preparation of radiopharmaceuticals can serve as an effective tool of radiation protection. The present study deals with the evaluation of the results of personal dosimetry in workers preparing the radiopharmaceutical 18F-FDG with the use of instrumental methods of preparation of this radiopharmaceutical. The results of the paper show a clear decrease in the values of finger dosimetry and a minute increase in the values of whole-body dosimetry in the cohort of pharmaceutical personnel. The evaluation thus shows a clear contribution of instrumental methods of preparation of the radiopharmaceutical 18F-FDG to the results of finger dosimetry of pharmaceutical personnel.

Keywords: automated preparation of radiopharma-ceuticals; radiation protection of staff; radiopharmacy

Received: November 3, 2020; Accepted: November 6, 2020; Published: May 1, 2020  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Budinský M, Vyšinský P, Synek S, Žilková K. Automated preparation of radiopharmaceuticals as a tool of radiation protection optimisation of staff. Čes. slov. farm. 2020;69(5-6):218-221. doi: 10.36290/csf.2020.030.
Download citation

References

  1. Demir M., Demir B., Yasar D., Sayman H. B., Halac M., Ahmed A. S., Ozcan K., Uslu I. Radiation doses to technologists working with 18F-FDG in PET center with high patient capacity. Nukleonika 2010; 55(1), 107-112.
  2. Roberts F. O., Gunawardana D. H., Pathmaraj K., Wallance A., U P. L., Berlangieri S. U., Graeme J. O'Keefe, Rowe C. C., Scott A. M. J. Radiation dose to PET technologists and strategies to lower occupational exposure. J. Nucl. Med. Technol. 2005; 33, 44-47.
  3. Guillet B., Quentin P., Waultier S., Bourrelly M., Pisano P., Mundler O. Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET. J. Nucl. Med. Technol. 2005; 33(3), 175-179.
  4. Rohren E. M., Turkington T. G., Coleman E. Clinical applications of PET in oncology. Radiology 2004; 231, 305-332. Go to original source... Go to PubMed...
  5. Bixler A., Springer G., Lovas R. Practical aspects of radiation safety for using fluorine-18. J. Nucl. Med. Technol. 1999; 27(1), 14-16.
  6. Antic V., Ciraj-Bjelac O., Stankovic J., Arandjic D., Todorovic N., Lucic S. Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia. Radiat. Prot. Dosim. 2014; 162(4), 577-585. Go to original source... Go to PubMed...
  7. Schleipman A. R., Gerbaudo V. H. Occupational Radiation Dosimetry Assessment Using an Automated Infusion Device for Positron-Emitting Radiotracers. J. Nucl. Med. Technol. 2012; 40(4), 244-248. Go to original source... Go to PubMed...
  8. Vanhavere F., Carinou E., Donadill L., Ginjaume M., Jankowski J., Rimpler A., Merce M. S. An overview of extremity dosimetry in medical applications. Radiat. Prot. Dosim. 2008; 123(1-3), 350-355. Go to original source... Go to PubMed...
  9. Lecchi M., Lucignani G., Maioli C., Ignelzi G., del Sole A. Validation of a new protocol for 18F-FDG infusion using an automatic combined dispenser and injector system. Eur. J. Nucl. Med. Mol. Imag. 2012; 39, 1720-1729. Go to original source... Go to PubMed...
  10. Budinsky M., Kozakova S. Experience with instrumental methods in radiopharmacy as a tool of radiation protection optimization Eur. J. Oncol. Pharm. 2018; 1, 0002. Go to original source...
  11. Covens P., Berus D., Vanhavere F., Caveliers V. The introduction automated dispensing and injection during PET procedures a step in the optimisation of extremity doses and whole body doses of nuclear medicine staff. Radiat. Prot. Dosim. 2010; 140(3), 250-258. Go to original source... Go to PubMed...
  12. Nazififard M., Mahdizadeh S., Meigooni A. S., Alavi M., Suh K. Y. A novel device for automatic withdrawal and accurate calibration of 99mtechnetium radiopharmaceuticals to minimise radiation exposure to nuclear medicine staff and patient. Rad. Prot. Dosim. 2012; 151, 469-477. Go to original source... Go to PubMed...
  13. Lindner O., Busch F., Burchert W. Performance of a device to minimise radiation dose to the hands during radioactive syringe calibration. Eur. J. Nucl. Med. Mol. Imag. 2003; 30, 819-825. Go to original source... Go to PubMed...
  14. Nazififard M., Mahdizadeh S., Suh K. Y. Automated dispensing and calibrating of diagnostic radiopharmaceuticals. Radiat. Prot. Dosim. 2013; 154, 510-516. Go to original source... Go to PubMed...




Czech and Slovak Pharmacy

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.